Issue:

You would like to use ELECTROWorx with a networked shared content folder.


Causes:

Plant 3d does not register new custom scripts to the networked shared content folder. You will need to temporarily change the shared content folder back to the default location. ie C:\AutoCAD Plant 3D 2024 Content


Solution:

  1. Open Autodesk Spec Editor for AutoCAD Plant 3D 2024 as Administrator.
  2. Change the Shared Content folder to its default location.
    • C:\AutoCAD Plant 3D 2024 Content
  3. Open AutoCAD Plant 3D and run PlantRegisterCustomScripts at the command line.
  4. Close Plant 3D.
  5. Copy the ELECTROWorx files from the default content folder to the networked Shared Content folder.
  6. Open Autodesk Spec Editor for AutoCAD Plant 3D 2024 as Administrator.
  7. Change the Shared Content folder to its networked location.
  8. Open AutoCAD Plant 3D and run PlantRegisterCustomScripts at the command line.
  9. Close Plant 3D.
  10. Open AutoCAD Plant 3D and test the ELECTROWorx specs.