Issue:

When trying to run Isogen out or Isogen Batch, we are getting an Error # 1054.

Causes:

This error comes up when the necessary Isogen DLL's are not registered.

Solution:

Check that your Drawing File paths are set correctly in IConfigure:



Make sure CADWorx and all Isogen programs are closed before attempting the option below. Check your Task Manager too.

2005 - 2015

1. Go to C:\CADWorx 20XX\Plant\Support 

2. Locate the Isogen.BAT file - right-click and run AS ADMINISTRATOR.

    a. Command Prompt dialog will appear and attempt to run all necessary DLL's in order to register

        the Isogen program. If all come back successful, proceed to step 3. If not successful, proceed to

        step "b".

    b.Manually run the dlls in the Command Prompt

    • Run the CMD.exe (DOS prompt) from the Windows Start button (right-click and run AS ADMINISTRATOR)

    • Run the following lines one by one (note version in path) ensuring each one is successful before continuing:
    • REGSVR32.EXE -u "C:\CADWorx 2015\Plant\Isogen\I-Configure\Personal Isogen\PISOGEN.DLL"
    • REGSVR32.EXE -u "C:\CADWorx 2015\Plant\Isogen\I-Configure\Core Components\IMPORTEXPORT.DLL"
    • REGSVR32.EXE -u "C:\CADWorx 2015\Plant\Isogen\I-Configure\Core Components\POD.DLL"
    • REGSVR32.EXE -u "C:\CADWorx 2015\Plant\Isogen\I-Configure\Core Components\PODTOOLS.DLL"
    • REGSVR32.EXE -u "C:\CADWorx 2015\Plant\Isogen\I-Configure\Core Components\MATERIALDATAWRAPPER.DLL"
    • REGSVR32.EXE -u "C:\CADWorx 2015\Plant\Isogen\I-Configure\Application Components\PIPELINE.DLL"
    • REGSVR32.EXE -u "C:\CADWorx 2015\Plant\Isogen\I-Configure\Application Components\SKEY.DLL"
    • REGSVR32.EXE -u "C:\CADWorx 2015\Plant\Isogen\I-Configure\Application Components\CATMANAGER.DLL"


    • REGSVR32.EXE "C:\CADWorx 2015\Plant\Isogen\I-Configure\Personal Isogen\PISOGEN.DLL"
    • REGSVR32.EXE "C:\CADWorx 2015\Plant\Isogen\I-Configure\Core Components\IMPORTEXPORT.DLL"
    • REGSVR32.EXE "C:\CADWorx 2015\Plant\Isogen\I-Configure\Core Components\POD.DLL"
    • REGSVR32.EXE "C:\CADWorx 2015\Plant\Isogen\I-Configure\Core Components\PODTOOLS.DLL"
    • REGSVR32.EXE "C:\CADWorx 2015\Plant\Isogen\I-Configure\Core Components\MATERIALDATAWRAPPER.DLL"
    • REGSVR32.EXE "C:\CADWorx 2015\Plant\Isogen\I-Configure\Application Components\PIPELINE.DLL"
    • REGSVR32.EXE "C:\CADWorx 2015\Plant\Isogen\I-Configure\Application Components\SKEY.DLL"
    • REGSVR32.EXE "C:\CADWorx 2015\Plant\Isogen\I-Configure\Application Components\CATMANAGER.DLL"
    • If all come back successful, proceed to step 3. If not successful, proceed to step "c".

    c. Files are not successful, CADWorx will need to be uninstalled and reinstalled using full

        ADMINISTRATOR rights.

3. Locate the Isogen64.BAT file - (right-click and run AS ADMINISTRATOR)

Note: Command Prompt dialog will flash on the screen.

4. Go back to CADWorx and run Isogen out.

2016 - 2017

1. Go to C:\CADWorx 201X\Plant\Isogen\I-Configure 

2. Locate the pisogenwrapper.bat file - right-click and run AS ADMINISTRATOR.

    a. Command Prompt dialog will flash and attempt to register the executible

        the Isogen program. If all come back successful, proceed to step 3. If not successful, proceed to

        step "b".

    b.Manually run the dlls in the Command Prompt

    • Run the CMD.exe (DOS prompt) from the Windows Start button (right-click and run AS ADMINISTRATOR)

    • Run the following lines one by one (note version in path) ensuring each one is successful before continuing:
    • C:\CADWorx 2017\Plant\Isogen\I-Configure\pisogenwrapper.exe   /unregserver
    • C:\CADWorx 2017\Plant\Isogen\I-Configure\pisogenwrapper.exe   /regserver


Notes:

This must all be done with full Administrator rights

Versions:

CADWorx Plant Professional 2005, CADWorx Plant Professional 2006, CADWorx Plant Professional 2007, CADWorx Plant Professional 2008, CADWorx Plant Professional 2009, CADWorx Plant Professional 2010, CADWorx Plant Professional 2012, CADWorx Plant Professional 2013, CADWorx Plant Professional 2014, CADWorx Plant Professional 2015, CADWorx Plant Professional 2016, CADWorx Plant Professional 2017